9 ASCII PRINTER OUTPUT OPTION
9.1 INTRODUCTION
If the Serial Communications option is
fi
tted, this allows the printing of messages, as and when they occur,
or the printing of con
fi
gurable reports as a result of job action. The recorder is set up to drive a number of
recommended printers. As more printers become available, printer drivers can be imported as described in
section 9.4
, below. For printer speci
fi
cation, refer to the documentation supplied with the printer.
9.2
WIRING
9.2.1 Serial communications ports
The printer is connected to one of the Serial communications ports, con
fi
gured for EIA232 standard, using the
Rx, Tx and common signal lines. Printer Tx must be connected to recorder Rx. Printer Rx must be connected
to recorder Tx. Figure 9.2.1 shows the location of, and user connections for, the recorder ports. See also
sec-
tion 2.2
.
Serial Port 1
Serial Port 2
EIA232C
Pin
1
2
3
4
5
6
7
8
9
Signal
NC
Rx
Tx
DTR
Signal ground
NC
NC
NC
5V via 1500
Ω
1
6
5
9
View on solder-bucket face
of user socket
Figure 9.2.1a Serial port locations (small frame)
Figure 9.2.1b Serial port pinout
9. 2.2 DC connection
+24V
0V
2
3
1
NC
Pin
Function
1
+24V±10%
2
0V
3
Not connected
Shell Chassis ground
Figure 9.2.2 DC connector pinout