6.6.4 Error messages
A number of error conditions may occur to prevent Bridge from ‘viewing’ the recorder. Such conditions result
in the appearance of one of the pop-up messages listed below:
NETWORK CONNECTION HAS TIMED OUT
This message appears when no connection can be established between the host pc and the instrument. This
might be caused by, for example, cable failure, the instrument’s not being powered, network hardware failure
etc.
UNABLE TO CONNECT TO HOST ...
Similar to the timeout message above, but with the additional cause: incorrect host address.
UNABLE TO RESOLVE HOSTNAME
Caused by an incorrect host address, or network failure.
FAILED TO AUTHENTICATE THE USER NAME ...
Caused by incorrect user name or password.
MAXIMUM NUMBER OF BRIDGE SESSIONS ALREADY RUNNING ON ...
An attempt is being made to establish more than the maximum number of Bridge sessions to the speci
fi
ed
instrument.
THERE APPEARS TO BE NO FREE DISK SPACE ON ...
Appears if there is insuf
fi
cient space on the PC hard disk.
YOU ARE ALREADY RUNNING A FULL BRIDGE SESSION ...
Appears if the pc is already connected to the recorder and running a Full Bridge session.
YOU ARE AUTHENTICATING FULL BRIDGE ...
Only Bridge ‘Lite’ is accessible to users using ‘Anonymous’.