25
2.1.3 Installing DeviceNet Master Board manufactured by molex
Appearance
Part names and functions of the DeviceNet master board manufactured by molex are
shown in the following figure.
For details of the status display LEDs (Module/NetWork LED and IO LED), refer to
4.
Troubleshooting
in this manual.
PCU-DVNIO
4-pin Terminal
Watchdog Port
(Do not use this port.)
DeviceNet Port
LED (2)
(Unused)
RJ45 Connector
(Unused)
Jumper pin for Board Address setting
C0 C1 C2
JP1
JP1
0
1
Status Display LED (2)
Specifications
Item
Specification
Name
DeviceNet master board manufactured by molex
Modes
Master
Baud rates
125, 250, 500 kbps
Interface
1 DeviceNet port
Supported Devices
Group 2 Only Server and U.C.M.M. capable
Maximum Nodes
63
Connection Types
Strobe, Polling, Cyclic and Change of State
Explicit Messaging
Connection
Yes
EDS Support
Yes
Max. Input Data Size
1024 bits (128 bytes)
Max. Output Data Size
1024 bits (128 bytes)
Automatic Detection
Yes. Devices can be detected automatically.
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...