4. Troubleshooting (DeviceNet)
288
RC700 / RC90 Option Fieldbus I/O Rev.14
(2)
Select the [DeviceNet (scanner)] tab. The window changes as shown below.
MAC ID
: MAC ID specified for the scanner board
Module/NetWork LED : Network Status (NS) LED status
IO LED
: Module Status (MS) LED status
applicomR Status
: Scanner board status
The scanner board status is shown in the “Code No. => Comment” form. The table
below shows the code numbers.
Status Code
Descriptions
General Protocol
0
No fault detected.
The function was performed correctly.
4
Inaccessible data.
Additional information:
The remote device is in error. Check its status.
32
The parameters passed to the functions are not
correct (eg: Number of requested variables too large)
33
Response time-out error.
Additional information:
The device does not respond. Check the device
status and the wiring.
The DeviceNet master has no device to be scanned in
the configuration.
34
Physical defect on the line.
Additional information:
No +24V power supply was detected.
The CAN component of the applicomIO® interface
is "Bus Off".
Check the network wiring and Baud Rate.
36
Device not configured.
Define the device configuration with the
applicomIO® Console and re-initiate the
initialization of the applicomIO® product by running
the PcInitIO
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...