2. Installation
178
RC700 / RC90 Option Fieldbus I/O Rev.14
Downloading to master board
40.
Right-click [netDevice]-<CIFX_RE_EIM> icon again, and click [Configuration…].
The [Configuration] dialog box appears.
41.
Click [Configuration]-[Address Table].
42.
Check the settings of [Address Table] and click <OK>.
“Address Table”-Inputs
Length: 0x0020
“Address Table”-Outputs Length: 0x0020
43.
Close the [Configuration] dialog box.
44.
Right-click [netDevice]-<CIFX_RE_EIM> icon and click [Download].
By the above step, “Setting on master side” and “Setting on slave side” are
downloaded to the EtherNet/IP board.
The settings are applied to EtherNet/IP board manufactured by Hilscher.