4. Troubleshooting (PROFIBUS DP)
RC700 / RC90 Option Fieldbus I/O Rev.14
293
4.2.2 Problems and Countermeasures
Master Unit LED
Error
Description [Reference]
BF
ST
Light
OFF
Green
Light
Blinking
Normal
communication
- Normal condition
Light
OFF
Green
Light ON
Ready for
communication
- Normal condition
Light
OFF
Red
Light
Blinking
Communication
error
[Refer to the section
4.2.2.1 Master
Communication Error
.]
- Slave disconnected from the network
(Remote I/O communication error)
- Slave not added to the network (Scan list
collation error)
- Nonstandard wiring
- No or too many terminating resistors
- Noise intrusion
Light
OFF
Red
Light ON
Data link layer
error
[Refer to the section
4.2.2.2 Master: Data
Link Layer Error
.]
- Nonstandard wiring
- Noise intrusion
Light
OFF
Light
OFF
Uninitialized
network
[Refer to the section
4.2.2.3 Master:
Uninitialized Network
.]
- Master unit power error
- Master unit configuration error
Red
Light ON
No
Matter
Physical error
[Refer to the section
4.2.2.4 Master:
Configuration Error
.]
- Nonstandard wiring
- Signal wire connection failure
- Signal wire short circuit
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...