2. Installation
212
RC700 / RC90 Option Fieldbus I/O Rev.14
LED Description
LED state represents the states of the fieldbus I/O board.
LED
State
Run LED
OFF
No network participation, timeout state (no power)
Green
Participating, normal operation
Red
Major fault (FATAL error)
Error LED
OFF
No error detected (no power)
Red
Major fault (Exception or FATAL event)
Red,
blinking
CRC error (temporary flickering)
Red, ON Station Number or Baud rate has changed since startup
(flashing)
Wiring
The CC-Link connector is a 5-pin open connector. Use the connector attached to the
module for wiring.
Terminal name for each pin
Terminal No Terminal Name
1
DA
2
DB
3
DG
4
SLD
5
FG
Connect the CC-Link master module and the CC-Link slave module as follows.
DA
DB
DG
SLD
FG
Terminating
Resistor
Master Station
DA
DB
DG
SLD
FG
DA
DB
DG
SLD
FG
CC-Link
Module
Twisted-pair Cable
with Shield
Robot System
CC-Link Module
Terminating
Resistor
Twisted-pair Cable
with Shield
Prepare the cable for CC-Link Ver.1.10 sold in the market as a communication cable.
Install terminating resistors at both ends of the network.
Use the terminating resistors attached to the CC-Link master station.
Make sure to disconnect the connectors only after turning OFF the power supply of
the specific station.
Connect the shield wire for CC-Link to the “SLD” of each unit and ground the both
ends via “FG”.
NOTE
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...