1. Diagnostic of the TCP/IP layer
This dialog box displays the status of the TCP/IP layer.
Configuration Type
Mode type selected in the configuration: DHCP,
BOOTP, Static
Address From
How the IP address has been obtained: from the server,
flash memory or factory address.
IP address
IP address of the applicomIO master on this channel.
Sub-Network Mask
Sub-network address of the applicomIO master on this
channel.
Gateway IP Address
Address of the gateway configured on the applicomIO
master on this channel.
Primary DNS Address
IP Address of the primary DNS server.
Secondary DNS Address
IP address of the secondary DNS server.
Host Name
Host name of the applicomIO master on this channel.
Domain Name
Domain name of the applicomIO master on this
channel.
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...