2. Installation
116
RC700 / RC90 Option Fieldbus I/O Rev.14
5. Confirm that the following items are displayed.
Fieldbus Type
: PROFIBUS-DP
Fieldbus Slave ID : (Displays the configure switch node address)
Type
: Byte (default setting)
Input Bytes
: 32 (default setting)
Output Bytes
: 32 (default setting)
6. Click <Close>.
Editing of Input / Output Size
You can change the input/output size of PROFIBUS-DP slave board if necessary.
1. Select [Setup]-[System Configuration] and display the [System Configuration] dialog
box.
2. Select [Inputs / Outputs]-[Fieldbus Slave]-[General].
3. Change the settings of [Input Bytes] and [Output Bytes].
In this example, both of them are changed to “20” Bytes.
The sum of input and output data sizes is restricted as follows:
For Byte format : 372 bytes
For Word format : 208 words
4. Click <Apply>.
Содержание RC700
Страница 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Страница 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Страница 74: ...2 Installation 62 RC700 RC90 Option Fieldbus I O Rev 14 17 DeviceNet Slave is connected and the icon appears ...
Страница 165: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 153 PCI CIFX 50 RE PCI Express CIFX 50E RE ...
Страница 183: ...2 Installation RC700 RC90 Option Fieldbus I O Rev 14 171 17 EtherNet IP Slave is connected and the icon appears ...
Страница 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...