Area measurements
Overlapping multi-part forms with labels
Same as labels except for the following:
The label on your form should be placed within the shaded area above,
but not on the vertical or horizontal perforation.
Area measurements
label
B
A
E
F
D
C
A 13
±
3 mm (0.51
±
0.12 inch)
B 80 mm (3.15 inches)
C 4.2 mm (0.165 inch)
D Thickness of the area where the label is attached:
0.53 mm (0.02 inch) or less
E From the perforation to the top of the next overlapping form:
3.3 mm (0.13 inch) or more
F From the perforation to the bottom edge of the glue point area:
17 mm (0.67 inch) or less
G From the perforation to the bottom edge of the previous
overlapping form: 13.3 mm (0.52 inch) or less
H Total thickness including glue point dilation:
0.7 mm (0.028 inch) or less
perforation
the bottom edge
of overlapping
form
the top of
overlapping form
the bottom edge of
the glue point area
(side view)
backing sheet
G
H
A
Me-200
A 19 mm (0.75 inch) or more
B 21.2 mm (0.84 inch) or more
C 4.2 mm (0.17 inch) or more
A
R
Peony
Rev.C
A5 size
Appendix A
98/01/07
pass 4
Specifications
A-11
Содержание C204001 - DFX 8500 B/W Dot-matrix Printer
Страница 1: ......
Страница 34: ...L Peony Rev C A5 size Chapter 1 98 01 07 Pass 4 1 16 Setting Up the Printer ...
Страница 56: ...L Peony Rev C A5 size Chapter 2 98 01 07 Pass 4 2 22 Setting Up Your Software ...
Страница 90: ...L Peony Rev C A5 size Chapter 3 98 01 07 Pass 4 3 34 Paper Handling ...
Страница 132: ...L Peony Rev C A5 size Chapter 5 98 01 07 pass 4 5 16 Using EPSON Status Monitor 2 ...
Страница 176: ...L Peony Rev C A5 size Chapter 7 98 01 07 Pass 3 7 6 Maintenance and Transportation ...
Страница 196: ...L Peony Rev C A5 size Chapter 8 98 01 07 DR pass 4 8 20 Troubleshooting ...
Страница 246: ...L Peony Rev C A5 size Glossary 98 01 07 Pass 2 GL 6 Glossary ...
Страница 252: ......