Epson Stylus Photo R280/R285/R290/Epson Artisan 50/Epson Stylus Photo T50/T59/T60/P50
Revision C
Chapter 4 Disassembly/Assembly
4.4.4 APG Unit (Disassembling the Printer Mechanism)
79
Confidential
Lubrication is required. See the page given below for the
lubrication information.
Lubrication of APG Unit (p.125)
Install the APG Unit following the procedure below.
1. Put a pin (thinner than Ø2mm) through the positioning
holes of the Main Frame and the right PG Cam on the CR
Shaft.
Figure 4-57. Reinstalling the APG Unit (1)
2. Put the pin through the positioning holes of the Spur gear
28.8 and the APG Unit.
Figure 4-58. Reinstalling the APG Unit (2)
Pin (1)
Positioning Hole
Right PG Cam
Spur Gear 28.8
APG Unit
Pin
Front: Positioning Hole of Spur Gear 28.8
Back: Positioning Hole of APG Unit
3. Install the APG Unit to the Main Frame.
Figure 4-59. Reinstalling the APG Unit (3)
4. Check that the hooks (
) are attached to the positioning
holes of the Main Frame, then screw the APG Unit.
Figure 4-60. Reinstalling the APG Unit (4)
Tighten the screws in the order given in
Fig.4-55 (p.78)
.
APG Unit
Pin
Main Frame