Please observe that with a humidity sensor, the humidity
setting will depend on the pre-set temperature. For safe-
ty reasons only the values to the left and under the curve
may be selected. For instance at 60 °C temperature you
can set up to 40 % rel. air humidity. In order to set a higher
humidity, you will first need to reduce the temperature.
If the sauna has been used in dry mode with high tem-
peratures and you switch to the humid mode, the vapor-
izer will only start to work after the temperature drops
under the max. allowed level (70 °C).
Time pre-selection (Auto-Start)
With this function you can program your sauna to switch on at a later time with up to 24 h delay.
In the main menu select and press the timer symbol
with the jog-dial. A
submenu will open and display “--:--“. Rotate the jog-dial to set the hour for
the desired automatic switch on time. Press on the jog-dial to confirm and
to jump to minutes. Now set the desired value for minutes and press the
jog-dial to save the setting and exit. At the start-screen you will see at the
bottom right the blinking timer with the programmed time. This time means
the time of day, not the delay in hours/minutes from the moment of setting.
To delete the pre-set Auto-Start timer simply press shortly on the on/off but-
ton. The blinking timer indication shall disappear.
Attention!
This function is only allowed to be used if your sauna is equiped with an
approved safety system, which prevents the heater from being switched on in an unsafe con-
dition (e.g. a towel forgotten on the heater). Even in the case if your sauna has such an ap-
proved system, assure yourself that there are no objects forgotten on the heater. Risk of fire!
How to dim the cabin light
The light button on the control panel
allows to switch the light on/off quickly. In the main
menu you can adjust the light brightness (dim the light 0-100%) via the same symbol. 0-10% in
single steps, 10-100% in 5 steps.
Press on the
light symbol with the jog dial. The cabin light will switch on (if not yet switched
on) and a submenu will open and display the current light setting in %. Rotate the jog-dial to ad-
just the brightness to the desired value. Press on the jog-dial shortly to confirm the new setting
and to exit the submenu.
Please observe that the light dimming will only function if a dimmable transformer or a regular
resistive load incandescent bulb has been connected. Make sure to observe the minimum and
maximum power load for the connected lamps (see specifications or contact your dealer).
10
100
90
80
70
60
50
40
30
20
0
100
90
80
70
60
50
40
30
20
10
T
[°C]
rH
[%]
20:51
15:59
20:51
15:59
Startzeit
Start time