25
EN
A
A
B
B
С
D
1. Determine a suitable location for the instal-
lation. The main sensor (heater sensor) must
be installed on the cabin ceiling above the
sauna heater. A second sensor (bench sen-
sor) can be installed above the back bench.
2. Drill a hole in the cabin ceiling for the cable.
3. NOTICE: Do not pull at the plug when routing
the control line(s). Doing so could damage
the line. Attach the taut wire only to the ca-
ble. Route the sensor cable through the hole.
4. Open the temperature sensor‘s housing and
connect the sensor bus cable.
5. Connect the lines for the overheating limiter
fuse (STB).
• The overheating limiter fuse is available
only in the main sensor. This step is not
necessary for the bench sensor because it
does not have an overheating limiter fuse.
• If multiple sauna heaters are installed in a
sauna cabin, it may be necessary to install
additional overheating limiter fuses and
connect them in series.
6. Screw the sensor plate to the cabin ceiling
and close the housing.
The main sensor must be installed where expected temperatures are the highest.
Ha tools:
• Temperature sensor and connecting cables
• Drill to drill a hole in the cabin ceiling
• Screwdriver
• Taut wire, as needed
Installing the temperature sensor
Installation scheme
sensor connections
A. STB
B. Leitungen (weiß)
safety temperature limiter connections
A. Cabin ceiling
B. Temperature sensor housing
C. RJ10 plug (sensor bus cable)
D. Line for overheating limiter fuse STB (2-pole)
weiß
grün
braun
For connection see chapter Electric Connec-
tions, Sensor.