23
EN
3
~ 80
65-70
15
127
130
5
alle Maße in mm
hier Kabeldurchführung
Pull the connection cable here
Mounting the display panel
The control line (S-Bus) that leads to the relay
box is connected to the con-trol panel
• Plug the control line with the RJ10 plug into
the circuit board.
• Place the front panel directly in front of the
bottom piece. Ensure that it is aligned prop-
erly.
• Press the front panel carefully with a consist-
ent amount of pressure into the housing un-
til it audibly snaps into place. The front panel
must sit firmly on the housing.
• Remove the protective foil from the display.
Mount the display panel by flush-mounting installation in
the same way.
S-Bus RJ10