26
EN
2
2
sensor connections
Marking on the main board
Installation configuration – bench sensor
white
green
brown
Upon correct connection, the sensor will be
automatically detected and configured. The
display will show the corresponding symbol
during start-up.
Indication on the display panel:
When connected the bench sensor will control
temperature after the initial heat-up phase. The
main sensor acts then as a temperature limiter.
This allows in certain situations, e.g. in very
large saunas with complex air circulation, to
optimise the heat distribution. If the bench
sensor fails, the heater sensor will overtake the
temperature control again.
Bench sensor requirements
Bench sensor installation
Temperature control
Bench sensor (optional)
The bench sensor is mounted on the ceiling
above the back sauna bench across from the
sauna heater.
The installation and connection of the bench
sensor is as of the main sensor. See chapter
„Sensor“ in installation section.
The bench sensor has no overheating tempera-
ture limiter (STB).
Содержание Emotec D