Connections
Recommended installation
sequence
As a rule, only a fixed connection may be con-
nected to the mains supply, whereby a con-
figuration is provided that makes it possible
to separate the system from the mains supply
with a contact opening width of at least 3 mm
(all poles).
All electrical installations and all connecting
lines that are installed inside a cabin must be
suitable for installation in a sauna or IR cabin
(IPx4).
The relay box is connected with a live current of
400 V 3 N ~ 50 Hz and fused separately with 3 x
16 A. A 16 A cut-out with at least K characteris-
tic must be used for fuse protection.
Before commencing installation, ensure that
the relay box, the control panel, and the tem-
perature sensor are mounted. Furthermore, all
cabin work must be complete: sauna heater,
light, humidity sensor if required, etc.
Complete installation in the following se-
quence:
• Plug the S-Bus and sensor lines into the relay
box.
• Connect the consumer lines (sauna heater,
light, fan, etc.) to the relay box.
• Establish connection to the power supply.
• In a multi-cabin installation: Program the
cabin address.
• Switch on the relay box and control panel.
• Configure additional settings at the control
panel, e.g. target temperature.
This chapter describes how to connect the re-
lay box‘s circuit board lines.
For information on setup of the control panel,
see chapter Commissioning
Electrical installation