37
EN
Connecting and configuring
consumers
Recommended sequence:
• Connect the cabin lighting
• Connect the fan
• Connect the sauna heater
• Connect the vaporiser (if necessary)
• Connect external device to the PFC if such
device is available.
• Connect the main connection
Auf maximal zulässige Leistung der ang-
eschlossenen Geräte achten:
• Light - chapter Installation > light
• Fan - chapter Installation > fan
• Potentialfree contact - chapter Installation
> Potentialfree contact (PFC)
• Sauna heater max. 9 kW
• Varporiser max. 3 kW
If the entire output exceeds these values, an
additional output controller must be connect-
ed, e.g. LSG18H. See the installation instruc-
tions for the relevant LSG.
WARNING
Risk of electric shock
A faulty electrical connection poses
the risk of an electric shock. This risk
also applies following completion of the instal-
lation work.
• Disconnect the system entirely from the
mains supply.
• If retrofitting is required, the housing must
only be opened by trained personnel.
• Electrical installation must only be carried
out by a qualified and licensed electrician.
• The unit must be connected to the power
supply according to the circuit diagram and
the terminal scheme.
Connecting consumers
•
WARNING! Ensure that the relay box has
no power. Open the housing
• Route the lines through the openings at the
base or on the back of the housing
• Connect consumers as per terminal connec-
tion diagram. Observe recommended se-
quence of connections.