18
EN
Potential free contact (PFC)
The relay box features a potential free contact.
You can include this NC (normally closed)
contact in any electric circuit to switch an ex-
ternal load or transmit a signal.
Maximum load
• Resistive load / alternating current 250 V
AC / 10 A
• Inductive load / alternating current 500 VA
• Direct current
• Up to 30 V DC max. 10 A (300 W)
• Up to 110 V DC max. 0,3 A (33 W)
• Up to 220 V DC max. 0,12 A (26,4 W)
NOTICE
Material damage due to short circuiting
The supply line can short circuit if you use the mains connections L1, L2 or L3 to supply the electric
circuit connected to the potential-free contact.
• Use the mains and other connections in the relay box only as shown in the connection dia-
gram.
• Do not connect additional devices to the mains connections of the relay box.
• Connect the device connected to the potential-free contact and ensure that it is protected
from short circuiting.
• Observe the maximum load of the potential-free contact.
Содержание Emotec D