Parameter overview with brief description
Parameter
Prerequisite
Description
Selection / User
interface / User
entry
Factory setting
Operating mode
–
Define the output as a pulse,
frequency or switch output.
• Pulse
• Frequency
• Switch
–
Terminal number
–
Shows the terminal numbers
used by the PFS output
module.
• Not used
• 24-25 (I/O 2)
• 22-23 (I/O 3)
–
Signal mode
–
Select the signal mode for the
PFS output.
• Passive
• Active
• Passive NAMUR
–
Assign pulse output 1 to n
The
Pulse
option is selected in
the
Operating mode
parameter parameter.
Select process variable for
pulse output.
• Off
• Mass flow
• Volume flow
• Corrected volume
flow
• Target mass flow
• Carrier mass flow
• Target volume
flow
• Carrier volume
flow
• Target corrected
volume flow
• Carrier corrected
volume flow
• GSV flow
• GSV flow
alternative
• NSV flow
• NSV flow
alternative
• S&W volume flow
• Oil mass flow
• Water mass flow
• Oil volume flow
• Water volume
flow
• Oil corrected
volume flow
• Water corrected
volume flow
–
Pulse scaling
The
Pulse
option is selected in
the
Operating mode
parameter (→ 88) and a
process variable is selected in
the
Assign pulse output
Enter quantity for measured
value at which a pulse is
output.
Positive floating
point number
Depends on country
and nominal
diameter
Pulse width
The
Pulse
option is selected in
the
Operating mode
parameter (→ 88) and a
process variable is selected in
the
Assign pulse output
Define time width of the
output pulse.
0.05 to 2
000 ms
–