Commissioning
Proline Promass E 300 Modbus RS485
84
Hauser
Navigation
"Setup" menu → Status input
‣
Status input 1 to n
Assign status input
Terminal number
Active level
Terminal number
Response time status input
Terminal number
Parameter overview with brief description
Parameter
Description
User interface / Selection / User entry
Terminal number
Shows the terminal numbers used by the status input module.
• Not used
• 24-25 (I/O 2)
• 22-23 (I/O 3)
Assign status input
Select function for the status input.
• Off
• Reset totalizer 1
• Reset totalizer 2
• Reset totalizer 3
• Reset all totalizers
• Flow override
• Zero point adjustment
Active level
Define input signal level at which the assigned function is
triggered.
• High
• Low
Response time status input
Define the minimum amount of time the input signal level must
be present before the selected function is triggered.
5 to 200 ms
10.3.8 Configuring the current output
The
Current output
wizard guides you systematically through all the parameters that have
to be set for configuring the current output.
Navigation
"Setup" menu → Current output
‣
Current output 1 to n
Terminal number
Signal mode
Assign current output 1 to n