Proline Promass E 300 Modbus RS485
Commissioning
Hauser
119
10.4.7 Configuration management
After commissioning, you can save the current device configurationor restore the previous
device configuration.
You can do so using the
Configuration management
parameter and the related options
found in the
Configuration backup
submenu.
Navigation
"Setup" menu → Advanced setup → Configuration backup
‣
Configuration backup
Operating time
Last backup
Configuration management
Backup state
Comparison result
Parameter overview with brief description
Parameter
Description
User interface / Selection
Operating time
Indicates how long the device has been in operation.
Days (d), hours (h), minutes (m) and seconds
(s)
Last backup
Shows when the last data backup was saved to HistoROM
backup.
Days (d), hours (h), minutes (m) and seconds
(s)
Configuration management
Select action for managing the device data in the HistoROM
backup.
• Cancel
• Execute backup
• Restore
• Compare
• Clear backup data
Backup state
Shows the current status of data saving or restoring.
• None
• Backup in progress
• Restoring in progress
• Delete in progress
• Compare in progress
• Restoring failed
• Backup failed
Comparison result
Comparison of current device data with HistoROM backup.
• Settings identical
• Settings not identical
• No backup available
• Backup settings corrupt
• Check not done
• Dataset incompatible
*
Visibility depends on order options or device settings