9. Operating the inverter
9.1 Identifying the parts
9.2 Operation procedure
Display part (LED display)
This part display frequency,
motor current, motor
rotation speed, alarm history,
and setting value.
POWER LED
On when the control
powerinput to inverter
is on
FUNCTION key
This key is used for
changing parameter
and command
(Example that the frequency is set from potentiometer to the standard operator and the
equipment starts running)
PRG LED
This LED is on when the
inverter is ready for
parameter editing.
RUN LED
on when the inverter
outputs the PWM
voltage and operating
command is ready
RUN key
Press this key to run the
motor. The Run enable
LED must be terminal
operation
UP/ DOWN key
This key is used to
change data and
increase or decrease
the frequency.
STORE KEY
Press the store key to write the
data and setting value to the
memory
Potentiometer
set the inverter output
frequency.(be operated
only when the ramp is
ON)
Hz/A LED
Display units Hertz/Ampere
LEDs.
STOP/RESET key
This key is used for stopping the motor or resetting
errors. (When either operator or terminal is selected,
this key works. If the extension function b 15 is used,
this function is void)
Display after
power is
turned on
060.0
F 01
01
60.0
0.0
F 01
01
A --
A--
A 01
A 01
0
chage the frequency
command by key
operation from the
potentiometer
set the frequency
to 60Hz
frequency monitor
Motor
Operation
Oper-
ation
start
press the key
once
press the key
once
press the key
9 times
press the key
press the key
once
press the key
once
press the key twice
press the key
four times
press the key
four times
Frequency
setting command
Hz
store the
data
display transition
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
STR
RUN
STR
store the data
POWER
RUN
PRG
A
Hz
RUN STOP/RESET MIN MAX
FUNC UP DOWN STR
0.0
9-1
ENDA E-100