Func-
code
Name
Description
External
frequency
start rate setting
External
frequency
end rate setting
External
frequency
sampling setting
Defaults
A07
A08
A10
The starting point(offset) for the active
analog input range(0¡10V, 4mA¡20mA)
setting range is 0 to 100% in units of 0.1%
The ending point(offset) for the active
analog input range(0¡10V, 4mA¡20mA)
setting range is 0 to 100% in units of 0.1%
Range n = 1 to 8, where n = number of
samples for average
0.0%
0
100.0%
4
¡
¡
¡
¡
0V
4mA
Frequency
Analog input
A06
A05
A07
A08
10V
20mA
A09=1
A09=0
Two options: select codes:
0.... start at start frequency
1.... start at 0Hz
Multi-speed Frequncy Setting
Multi-speed
frequency
setting
Jogging
frequency
setting
Jogging stop
operation
selection
A11
A25
A26
A27
Defines limited speed for jog,
range is 0.5 to 10.00Hz in units of 0.01Hz.
The jogging frequency is provided safety
during manual operation.
Define how end of jog stops the motor:
three options:
0.... Free-run stop
1.... Deceleration stop(depending on
deceleration time)
2.... DC braking stop(necessarg to set
DC braking)
0.50Hz
0
speed1:5Hz
speed2:10Hz
speed3:15Hz
speed4:20Hz
speed5:30Hz
speed6:40Hz
speed7:50Hz
speed8:60Hz
etc. 0Hz
¡
¡Defines the first speed of a multi-
speed profile, range is 0 to 400Hz in
units of 0.01Hz.
¡Setting range is 1-speed(A11) to
15-speed(A25).
¡Speed0:volume setting value
¡
¡
¡
Run-
time
Edit
External
frequency start
pattern setting
A09
9-8
ENDA E-100
INSTRUCTION MANUAL