Parameter Monitoring Functions
Func-
code
Name
Description
d01
d02
d03
d04
d05
d06
d07
d08
Output frequency
monitor
Output current monitor
Output voltage monitor
Rotation direction
monitor
PID feedback monitor
Intelligent input terminal
status
Intelligent output
terminal status
Scaled output frequency
monitor
Real-time display of output frequency to
motor, from 0.00 to 400.0 Hz, "Hz" LED ON
Real-time display of output current to motor,
from 0.0 to 99.9A, "A" LED ON.
Real-time display of output voltage to motor
Three different indications:
"F"..... Forward Run
"
¤
"... Stop
"r"...... Reverse Run
Displays the scaled PID process variable
(feedback) value (A50 is scale factor)
Displays the state of the intelligent input
terminals:
ON
OFF
5 4 3 2 1
Terminal numbers
Displays the state of the intelligent output
terminals:
11
Displays the output frequency scaled by the
constant in b14.
Scale factor(b14)
x
frequency data
Function List
9-4
ON
OFF
Terminal numbers
ENDA E-100