Output frequency
Forward
Reverse
SWF
SWR
ON
OFF
ON
OFF
OFF
OFF
SWR
RV
2
SWF
FW
1
CM1
5 4 3 2
L
1
2CHCF2 CF1 RV FW
CM1
Frequency
(Hz)
[4-Stage speed]
Switch
ON
RV
FW
CF2
CF1
ON
ON
ON
ON
ON
ON
Default Terminal
setting
1 : FW
Terminal2 : RV
Terminal3 : CF1
Terminal4 : CF2
Terminal5 : 2CH
Terminal
8. Using intelligent terminals
8.1 Intelligent terminal lists
Terminal
symbol
Description
FW
(0)
Forward
RUN/STOP
terminal
Reverse
RUN/STOP
terminal
SWF Switch
ON (closed):Forward run
OFF(open): stop
SWR Switch
ON (closed):Reverse
run
OFF(open): stop
1
2
3
4
Multi-speed
frequency
commanding
terminal
Jogging
Jogging operation
EXT
(9)
USP
(10)
SFT
(11)
AT
(12)
RS
(13)
In
te
ll
ig
en
t
In
p
u
t
T
er
m
in
al
(1
¡5
)
RV
(1)
CF1
(2)
CF2
(3)
CF3
(4)
CF4
(5)
JG(6)
2CH
(7)
FRS
(8)
2-stage acceler-
ation/deceleration
The acceleration or deceleration time is possible to change
considering the system.
Free-run stop
External trip
Unattended start
prevention
Current input
selection
Reset
Terminal soft-
ware lock
The inverter stops the output and the motor enters the free-
run state.(coasting)
It is possible to enter the external trip state.
Restart prevention when the power is turned on in the RUN
state.
The data of all the parameters and functions except the output
frequency is locked.
The [AT] terminal selects whether the inverter uses the voltage
[O] or current [OI] input terminals for external frequency control.
If the inverter is in Trip Mode, the reset cancels the Trip Mode.
When SWF and SWR commands are active at the same
time, the inverter stops
0-speed
3-speed
2-speed
1-speed
Terminal name
8-1
ENDA E-100
INSTRUCTION MANUAL