C13
C17
C15
5
0
0
Intellingent
output
terminal 11
setting
Select function for terminal 11
<code>
0... RUN(Run signal)
1.... FA1(Frequency arrival signal:
command arrival)
2.... FA2(Frequency arrival signal:
setting frequency or more)
3.... OL(Overload advance notice
signal)
4.... OD(Output deviation for PID
control)
5.... AL(Alarm signal)
Select function for terminal FM,
3 options
0.... output frequency monitor
1.... output current monitor
2.... output voltage monitor
Select logic convention, two option
codes:
0.... normally open [NO]
1.... normally closed [NC]
¡
¡
¡
Output Terminal Function
Montor signal
selection
Output Terminal 11
a/b contact setting
Select logic convention, two option codes:
0.... normally open [NO]
1.... normally closed [NC]
Select logic convention, two option codes:
0.... normally open [NO]
1.... normally closed [NC]
Input Terminal 4
a/b contact setting
(NO/NC)
Input Terminal 5
a/b contact setting
(NO/NC)
C10
C11
0
0
¡
¡
Func-
code
Name
Description
Defaults
Run-
time
Edit
Func-
code
Name
Description
Defaults
9-19
ENDA E-100
INSTRUCTION MANUAL