27. SYSTEM NOTIFICATIONS
In case of a certain event, the system attempts to send an SMS text message to the first listed user phone number only. If the user phone
number is unavailable and the system fails to receive the SMS delivery report during 45 seconds, it will attempt to send the SMS text mes-
sage to the next listed user phone number, assigned to the same partition as the previous one. The user phone number may be unavailable
due to the following reasons:
• mobile phone was switched off.
• was out of GSM signal coverage.
The system will continue sending the SMS text message to the next listed user phone numbers in the priority order until one is available.
The system sends the SMS text message only once and will not return to the first user phone number if the last one was unavailable.
The following table provides the description of system notifications by SMS text message sent to the user phone number.
Seq. No.
Event
Description
1
General alarm
SMS text message sent to the user in case of system alarm occurrence.
2
System disarmed
SMS text message sent to the user about disarmed system.
3
System armed
SMS text message sent to the user regarding armed system.
4
Mains power loss
SMS text message sent to the user in case the mains power is lost.
5
Mains power restore
SMS text message sent to the user in case the mains power supply is restored
6
Low battery
SMS text message sent to the user in case the backup battery voltage is 10.5V or lower
7
Periodical info
Info SMS text message sent to the user periodically by the set values.
8
Tamper alarm
SMS text message sent to the user in case of tamper violation. Indicated as
Tamper x
.
9
Battery failed
SMS text message sent to the user in case the backup battery resistance is 2Ω or higher (battery
requires replacement).
10
System started
SMS text message sent to the user on system startup.
11
Wireless signal loss
SMS text message sent to the user in case the wireless signal is lost. Indicated as
Tamper x *
.
12
Temperature fallen
SMS text message sent to the user in case of temperature deviation by the set MIN value.
13
Temperature exceeded SMS text message sent to the user in case of temperature deviation by the set MAX value.
14
System shutdown
When the system is running on backup battery power, it sends the SMS text message to the user
before the backup battery power is fully depleted.
ATTENTION:
The following methods provide the configuration of the master parameters, which override the notification parameters de-
scribed in
12.9. Disabling and Enabling Arm/Disarm Notifications
.
To disable/enable a certain system notification, please refer to the following configuration methods.
Disable system
notification
EKB2
Menu path:
General alarm:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ALARM EVENT
→
OK
→
DISABLE
→
OKK
System armed:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ARMED EVENT
→
OK
→
DISABLE
→
OK
System disarmed:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
DISARMED EVENT
→
OK
→
DISABLE
→
OK
Mains power loss:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
MAIN PWR LOSS EV
→
OK
→
DISABLE
→
OK
Mains power restore:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
MAIN PWR REST EV
→
OK
→
DISABLE
→
OK
Low battery:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
LOW
BATTERY EVENT
→
OK
→
DISABLE
→
OK
Battery failed:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
BATTERY FAIL EVENT
→
OK
→
DISABLE
→
OK
Periodical info: O
K
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
PERIODIC SMS EV
→
OK
→
DISABLE
→
OK
Tamper alarm:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TAMPER EVENT
→
OK
→
DISABLE
→
OK
System started:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
SYSTEM STARTED EV
→
OK
→
DISABLE
→
OK
Wireless signal loss:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
WLESS SIGN LOSS EV
→
OK
→
DISABLE
→
OK
System shutdown:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
SYSTEM SHUTDOWN EV
→
OK
→
DISABLE
→
O
K
Temperature fallen:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TEMP LOW EVENT
→
OK
→
DISABLE
→
OK
Temperature exceeded:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TEMP HIGH EVENT
→
OK
→
DISABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 25, event number and parameter status value:
25 01 0 #
- General alarm
25 02 0 #
- System armed
25 03 0 #
- System disarmed
25 04 0 #
- Mains power loss
25 05 0 #
- Mains power restore
25 06 0 #
- Low battery
25 07 0 #
- Battery failed
25 08 0 #
- Periodical info
25 10 0 #
- Tamper alarm
25 11 0 #
- System started
25 12 0 #
- Wireless signal loss
25 13 0 #
- System shutdown
25 14 0 #
- Temperature fallen
25 15 0 #
- Temperature exceeded
Example:
25040#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Enable system
notification
EKB2
Menu path:
General alarm:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ALARM EVENT
→
OK
→
ENABLE
→
OKK
System armed:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
ARMED EVENT
→
OK
→
ENABLE
→
OK
System disarmed:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
DISARMED EVENT
→
OK
→
ENABLE
→
OK
Mains power loss:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
MAIN PWR LOSS EV
→
OK
→
ENABLE
→
OK
Mains power restore:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
MAIN PWR REST EV
→
OK
→
ENABLE
→
OK
Low battery:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
LOW
BATTERY EVENT
→
OK
→
ENABLE
→
OK
Battery failed: O
K
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
BATTERY FAIL EVENT
→
OK
→
ENABLE
→
OK
Periodical info:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
PERIODIC SMS EV
→
OK
→
ENABLE
→
OK
Tamper alarm:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TAMPER EVENT
→
OK
→
ENABLE
→
OK
System started:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
SYSTEM STARTED EV
→
OK
→
ENABLE
→
OK
Wireless signal loss:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
WLESS SIGN LOSS EV
→
OK
→
ENABLE
→
OK
System shutdown:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
SYSTEM SHUTDOWN EV
→
OK
→
ENABLE
→
OK
Temperature fallen:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TEMP LOW EVENT
→
OK
→
ENABLE
→
OK
Temperature exceeded:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
SMS MESSAGES
→
OK
→
TEMP HIGH EVENT
→
OK
→
ENABLE
→
OK
Value:
aaaa
– 4-digit administrator password.
Содержание ESIM264
Страница 60: ...MadeintheEuropeanUnion www eldes lt...