MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
31. WIRED DEVICES
31.1. RS485 Interface
The system comes equipped with RS485 interface used for the communication with the following devices:
• EKB2 - LCD keypad. Up to 4 units supported.
• EKB3 - LED keypad. Up to 4 units supported.
• EPGM1 - hardwired zone and PGM output expansion module. 1 unit supported.
The terminals of RS485 interface are Y (yellow wire) and G (green wire) terminals, which are data bus. The devices, connected to RS485
interface, must be powered from the AUX+ and AUX- terminals or by an external power supply.
For more details on RS485 device wiring, please refer to
3.2.7. RS485
.
For more details on technical specifications and installation, please refer to the latest user manual of the device located at www.eldes.lt/
download
31.1.1. EKB2 - LCD Keypad
Main features:
• Alarm system arming and disarming (see
12.3. EKB2 Keypad and User Code
).
• Arming and disarming in Stay mode (see
15. STAY MODE
).
• System parameter configuration (see
5. CONFIGURATION METHODS
).
• PGM output control (see
18.4. Turning PGM Outputs ON and OFF
).
• System information display (see
31.1.1.1. Icons and Messages
).
• Keypad partition switch (see
23.3. Keypad Partition and Keypad Partition Switch
).
• Audio indication by built-in buzzer.
• Wireless device information display (see
19.2. Wireless Device Information
).
• Temperature display (see
31.1.1.1. Icons and Messages
).
• Time display (see
31.1.1.1. Icons and Messages
).
For more details on technical specifications and installation, please refer to the latest user manual of the device located at www.eldes.lt/
download
31.1.1.1. Icons and Messages
READY
GARAGE
TBL
BYP
STAY
00:45
20,2
0
C
GSM signal
strength
System
status
message
Home screen
view
One or more
violated
zones are
bypassed
System
armed in Stay
mode
One or
more
system
faults are
present
Custom
partition
name
Digital
clock
Temperature
43
Icon / Message
Description
Chime - Delay zone violated when system
is disarmed.
Exit delay countdown initiated.
System is armed and menu is locked.
System is disarmed and menu is unlocked
+ CONFIGURATION
MODE
Configuration mode activated.
BURGLARY ALARM
Delay, Instant or Follow zone violated
when system is armed.
Icon / Message
Description
24 ALARM
24H zone violated.
FIRE ALARM
Fire zone violated.
TAMPER ALARM
Tamper violated
READY
System is ready to be armed.
NOT READY
System is not ready to be armed – one or
more zones / tampers violated.
ARMED
System is armed (optional feature).
STAY
Stay
mode activated
BYP
System armed in Stay mode
TBL
One or more system faults are present
Содержание ESIM264