MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Set primary connection
EKB2
Menu path:
GPRS network:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY CONNECTION
→
OK
→
GPRS
→
OK
Voice calls:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY
CONNECTION
→
OK
→
VOICE CALLS
→
OK
RS485:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY
CONNECTION
→
OK
→
RS485
→
OK
CSD:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY
CONNECTION
→
OK
→
CSD
→
OK
SMS:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY
CONNECTION
→
OK
→
SMS
→
OK
connection not in use:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
PRIMARY CONNECTION
→
OK
→
N/A
→
OK
Value:
aaaa – 4-digit administrator password.
EKB3
Enter parameter 48 and communication method number:
48 0 #
– GPRS network
48 1 #
– Voice calls
48 2 #
– RS485
48 3 #
– CSD
48 4 #
– SMS
Example:
484#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
Set backup connection
1... 4
EKB2
Menu path:
GPRS network:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP CONNECTION1... 4
→
OK
→
GPRS
→
OK
Voice calls:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP
CONNECTION1... 4
→
OK
→
VOICE CALLS
→
OK
RS485:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP
CONNECTION1... 4
→
OK
→
RS485
→
OK
CSD:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP CONNECTION1... 4
→
OK
→
CSD
→
OK
SMS:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP
CONNECTION1... 4
→
OK
→
SMS
→
OK
connection not in use:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
BACKUP CONNECTION1... 4
→
OK
→
N/A
→
OK
Value:
aaaa
– 4-digit administrator password.
EKB3
Enter parameter 83, backup connection slot number and communication method
number:
83 bb 0 #
– GPRS network
83 bb 1 #
– Voice calls
83 bb 2 #
– RS485
83 bb 3 #
– CSD
83 bb 4 #
– SMS
83 bb 5 #
– connection not in use
Value:
bb –
backup connection slot number, range – [01... 04].
Example:
83031#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
If all attempts by all set connections are unsuccessful, the system will wait until the delay time (By default – 600 seconds) expires and will
attempt to transmit data to the monitoring station again starting with the primary connection.
Set delay after last
communication
attempt
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
MS SETTINGS
→
OK
→
DELAY LAST ATTEMPT
→
OK
→
aaapp
→
OK
Value:
aaaa
– 4-digit administrator password;
aaapp
– duration of delay after last attempt,
range – [0... 65535] seconds.
EKB3
Enter parameter 69 and duration of delay after last attempt:
69 aaapp #
Value:
aaapp
– duration of delay after last attempt, range – [0... 65535] seconds.
Example:
69200#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
NOTE:
0 value disables delay after last communication attempt.
NOTE:
The system is fully compatible with Kronos NET/Kronos LT monitoring station software for communication via GPRS network. When
using a different monitoring station software, EGR100 middleware is required. EGR100 is freeware and can be downloaded at www.eldes.lt/
en/download. Alternatively, you can use ESR100 digital receiver. For more details, please refer to www.eldes.lt
30.2.1. GPRS Network
The system supports data transmission to the monitoring station via IP-based networks by GPRS network. The supported data formats are the
following:
• EGR100
• Kronos
To set up the system for data transmission via GPRS network, please follow the basic configuration steps:
1.
Enable MS Mode parameter (see
30. MONITORING STATION
).
2.
Set 4-digit Account number (see
30. MONITORING STATION
).
3.
Set server IP address, which is a public IP address of ESR100 digital receiver or the machine running EGR100 or Kronos monitoring station
software.
4.
Set public server port, which is a port of ESR100 digital receiver or the machine running EGR100 or Kronos monitoring station software.
5.
Select TCP or UDP protocol. UDP is highly recommended for EGR100 data format.
6.
Select data format: EGR100 or Kronos.
7.
In case EGR100 is selected, set 4-digit Unit ID number. Unit ID number can be identical to Account number.
8.
Set up APN, user name and password provided by the GSM operator. De pending on the GSM operator, only APN might be required to set
up.
For detailed step-by-step instructions on how to establish the communication between ESIM264 alarm system and EGR100 middleware, please
refer to the middle-ware’s HELP file.
Set server IP address
SMS
SMS text message content:
ssss_SETGPRS:IP:add.add.add.add
Value:
ssss
– 4-digit SMS password;
add.add.add.add
– server IP address.
Example:
1111_SETGPRS:IP:65.82.119.5
EKB2
Menu path:
OK
→
CONFIGURATION
→
OK
→
aaaa
→
OK
→
GPRS SETTINGS
→
OK
→
SERVER IP
→
OK
→
add.add.add.add
→
OK
Value:
aaaa
– 4-digit administrator password;
add.add.add.add –
server IP address.
EKB3
Enter parameter 40 and server IP address:
40 add add add add #
Value:
add add add add
– server IP address.
Example:
40065082119005#
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.