MANUAL ELDES ESIM264 V3.2
MANUAL ELDES ESIM264 V3.2
Arm the system
1
7
4
2
8
5
0
3
9
6
Enter user code:
uuuu
→
OK
Value:
uuuu
– 4-digit user code.
Example:
1111
→
OK
To cancel the system arming process, enter the user code again during exit delay countdown.
To disarm the system by EKB2 keypad, enter any out of 30 available 4-digit user codes using the number keys on the keypad. When a valid
user code is entered, the keypad will display icon for 3 seconds and switch to home screen view.
Disarm the system
1
7
4
2
8
5
0
3
9
6
Enter user code:
uuuu
→
OK
Value:
uuuu
– 4-digit user code.
Example:
1111
→
OK
The system will arm/disarm the partition corresponding to the one that user code and the key pad are assigned to. For example, if EKB2 keypad
and user code is assigned to Partition 1, the user will be able to arm/ disarm only Partition 1. For more details on how to set user code and
keypad partition, please refer to
23.4. User Code Partition
and
23.3. Keypad Partition and Keypad Partition Switch respectively.
To arm/disarm a different partition than the keypad is assigned to, use keypad partition switch feature (by default – disabled) before arming/
disarming process. For more details on keypad partition switch and how to enable it, please refer to
23.3. Keypad Partition and Keypad
Partition Switch.
Use keypad partition
switch
Menu path:
P1
→
[p] part-name
→
OK
Value
:
part-name
– up to 15 characters partition name.
NOTE:
If the user fails to enter a correct user code 10 times in a row, the system will block the keypad for 2 minutes and the keypad will
display
KEYPAD BLOCKED
message. While the keypad is blocked, the system prevents from entering any user code. The keypad will auto-
matically unblock once the 2-minute time has expired and display
KEYPAD
UNBLOCKED
message.
12.4. EKB3 Keypad and User Code
EKB3
Illuminated indicator READY on EKB3 keypad indicates that no violated zones and/or tampers are present, therefore the system
can be armed. If the indicator is not illuminated, the user must restore all violated zones and tampers before arming the system.
Alternatively, the violated zones can be bypassed (see
14.7. Bypassing and Activating Zones
), disabled (see
14.9. Disa-
bling and Enabling Zones
) or a Force attribute enabled (see
14.6. Zone Attributes
).
To arm the system by EKB3 keypad, enter any out of 30 available 4-digit user codes using the number keys on the keypad (see
10. USER CODES
for user code management). By default, when a valid user code is entered, the system will initiate exit delay,
the keypad’s buzzer will emit short beeps and the indicator ARMED will light ON. When the system is successfully armed, the
keypad’s buzzer will silent down.
Arm the system
1
7
4
2
8
5
0
3
9
6
Enter user code:
uuuu
Value:
uuuu
– 4-digit user code.
Example:
1111
To cancel the system arming process, enter the user code again during exit delay countdown.
To disarm the system by EKB3 keypad, enter any out of 30 available 4-digit user codes using the number keys on the keypad. When a valid
user code is entered, EKB3 keypad indicator ARMED will light OFF.
Disarm the system
1
7
4
2
8
5
0
3
9
6
Enter user code:
uuuu
Value:
uuuu
– 4-digit user code.
Example:
1111
The system will arm/disarm the partition corresponding to the one that user code and the key pad are assigned to. For example, if EKB3
keypad and user code is assigned to Partition 0, the user will be able to arm/ disarm only Partition 0. For more details on how to set user
code and keypad partition, please refer to
23.4. User Code Partition
and
23.3. Keypad Partition and Keypad Partition Switch re-
spectively.
To arm/disarm a different partition than the keypad is assigned to, use keypad partition switch feature (by default – disabled) to switch the
keypad to a different partition before arm ing/disarming process. For more details on keypad partition switch and how to enable it, please
refer to
23.3. Keypad Partition and Keypad Partition Switch.
Use keypad partition
switch
Hold the [*] key, release it after 3 short beeps and enter partition number:
* p
Value:
p – partition number, range – [0... 1]
Example:
*1
NOTE:
By default, User Code 1 is listed as
1111
and assigned to Partition 0.
12.5. iButton Key
To arm or disarm the system, touch the iButton key reader by any of 5 available iButton keys (see
11. iBUTTON KEYS
for iBut-
ton key management). When the iButton is touched to the iButton key reader for arming, the system will proceed as follows:
• If ready (no violated zone/tamper), the system will initiate exit delay and arm.
• If unready, the system will not arm and provide a list of violated zones/tampers by SMS text message to user phone
number. In such case the user must restore all violated zones and tampers before arming the system. Alternatively, the
violated zones can be bypassed (see
14.7. Bypassing and Activating Zones
), disabled (see
14.9. Disabling and
Enabling Zones
) or a Force attribute enabled (see
14.6. Zone Attributes
).
33
The system will arm/disarm the partition corresponding to the one that the iButton key is assigned to. For more details on how
to set iButton key partition, please refer to
23.5. iButton Key Partition.
12.6. EWK1/EWK2 Wireless Keyfob
EWK1/
EWK2
To arm the system, press 1 of 4 keyfob buttons set to arm the system (by default, EWK1 –
;EWK 2 -
). When EWK1/
EWK2 button is pressed for arming, the system will proceed as follows:
• If ready (no violated zone/tamper), the system will initiate exit delay and arm.
• If unready, the system will not arm. In such case the user must restore all violated zones and tampers before arming
the system. Alternatively, the violated zones can be bypassed (see
14.7. Bypassing and Activating Zones
), disa-
bled (see
14.9. Disabling and Enabling Zones
) or a Force attribute enabled (see
14.6. Zone Attributes
).
Arm the
system
34
Arm
the
system
34
To disarm the system, press 1 of 4 keyfob buttons set to disarm the system (by default, EWK1 -
; EWK2 -
).
Содержание ESIM264
Страница 60: ...MadeintheEuropeanUnion www eldes lt...