99 Thermostat 1 - Humidity value (1 byte, from bus)
1 Byte
-WCTU-
[5.1] DPT_Scaling
100 Thermostat 1 - Antistratification temperature (from
bus)
2 Bytes
-WCTU-
[9.1] DPT_Value_Temp
101 Thermostat 1 - Outdoor temperature (from bus)
2 Bytes
-WCTU-
[9.1] DPT_Value_Temp
102 Thermostat 1 - Coil temperature (from bus)
2 Bytes
-WCTU-
[9.1] DPT_Value_Temp
103 Thermostat 1 - Floor temperature (from bus)
2 Bytes
-WCTU-
[9.1] DPT_Value_Temp
104 Thermostat 1 - Flow temperature (from bus)
2 Bytes
-WCTU-
[9.1] DPT_Value_Temp
105 Thermostat 1 - Windows contact sensor 1 (from
bus)
1 Bit
-WCTU-
[1.19]
DPT_Window_Door
106 Thermostat 1 - Windows contact sensor 2 (from
bus)
1 Bit
-WCTU-
[1.19]
DPT_Window_Door
107 Thermostat 1 - Presence sensor 1 (from bus)
1 Bit
-WCTU-
[1.18] DPT_Occupancy
108 Thermostat 1 - Presence sensor 2 (from bus)
1 Bit
-WCTU-
[1.18] DPT_Occupancy
109 Thermostat 1 - Contact of card holder (from bus)
1 Bit
-WCTU-
[1.18] DPT_Occupancy
110 Thermostat 1 - Anticondensation (from bus)
1 Bit
-WCTU-
[1.1] DPT_Switch
111 Thermostat 1 - Weighted temperature
2 Bytes
R-CT--
[9.1] DPT_Value_Temp
112 Thermostat 1 - Heating/cooling status out
1 Bit
R-CT--
[1.100] DPT_Heat_Cool
113 Thermostat 1 - Heating/cooling status in
1 Bit
-WC---
[1.100] DPT_Heat_Cool
114 Thermostat 1 - HVAC mode in
1 Byte
-WC---
[20.102]
DPT_HVACMode
115 Thermostat 1 - HVAC forced mode in
1 Byte
-WC---
[20.102]
DPT_HVACMode
116 Thermostat 1 - HVAC mode out
1 Byte
R-CT--
[20.102]
DPT_HVACMode
117 Thermostat 1 - HVAC manual mode
1 Byte
RWCTU- [20.102]
DPT_HVACMode
118 Thermostat 1 - Chrono status
1 Bit
R-CT--
[1.11] DPT_State
119 Thermostat 1 - Actual setpoint
2 Bytes
R-CT--
[9.1] DPT_Value_Temp
120 Thermostat 1 - Manual setpoint
2 Bytes
-WC---
[9.1] DPT_Value_Temp
121 Thermostat 1 - Comfort setpoint (heating)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
121 Thermostat 1 - Setpoint in
2 Bytes
-WC---
[9.1] DPT_Value_Temp
122 Thermostat 1 - Comfort setpoint (cooling)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
123 Thermostat 1 - Standby setpoint (heating)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
123 Thermostat 1 - Offset standby (heating)
2 Bytes
RWCTU- [9.2] DPT_Value_Tempd
124 Thermostat 1 - Standby setpoint (cooling)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
124 Thermostat 1 - Offset standby (cooling)
2 Bytes
RWCTU- [9.2] DPT_Value_Tempd
125 Thermostat 1 - Economy setpoint (heating)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
125 Thermostat 1 - Offset economy (heating)
2 Bytes
RWCTU- [9.2] DPT_Value_Tempd
126 Thermostat 1 - Economy setpoint (cooling)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
126 Thermostat 1 - Offset economy (cooling)
2 Bytes
RWCTU- [9.2] DPT_Value_Tempd
127 Thermostat 1 - Building protection setpoint (heating)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
128 Thermostat 1 - Building protection setpoint (cooling)
2 Bytes
RWCTU- [9.1] DPT_Value_Temp
129 Thermostat 1 - Room temperature controller status
1 Bit
R-CT--
[1.3] DPT_Enable
130 Thermostat 1 - Heating out command
1 Byte
R-CT--
[5.1] DPT_Scaling
130 Thermostat 1 - Heating out command 1bit
1 Bit
-WC---
[1.1] DPT_Switch