EPX400-A20CU – Manual
Page 35 / 62
Wired output
8.4.2.
Output reaction time
8.4.2.1.
Thanks to this option you may choose output operation mode. There are two
operation modes available:
o
always – connection follows for indefinite time – up to the moment of
disconnection of power for module or remote command which switches output
off,
o
for the specific time – connection follows for time defined by user.
Additional activation conditions
8.4.2.2.
In this section you can define conditions for activating of outputs.
User can set following conditions:
When mobile network watchdog - activation of the output when connector has
registered loss of cellular network,
When mobile data watchdog – activation of the output when connector has
registered loss of mobile transmission,
When Ethernet watchdog - activation of the output when connector has
registered loss of Ethernet transmission
No connection to server (immediately after detection),
No GSM signal (immediately after detection)
When incoming call detected from defined telephone number
After selecting this option below will display a new field to enter telephone number.
Additional, after enable this option, can be generated CLIP event, if appropriate
position in the “Monitoring” group is set (see TCP/IP monitoring chapter, ). You can