After clicking on the list to open it, you can select a value from 5 minutes to
maximum (no period of validity).
Limits
8.4.3.3.
In this section you can limit the number of text messages to be sent by the device.
Extra fields will be shown after selecting option “Active”:
Maximum number
—
in this field you can define the number of text messages
per time unit (see the parameter Resetting the counter). This option prevents the
user from sending too many messages, e.g. in case of a failure.
Resetting the counter
— in this field you can define the period for resetting the
counter of sent text messages: from 5 minutes to 3 days.
The following types of information may be subjected to limitations (depending on the
fact whether it is selected or not):
Cyclical tests sent to the server,
Events sent to the server,
Events sent to the user,
Answers to text message commands
SMS forwarding 0/5
8.4.3.4.
The device is able to transmit the received text messages to the specified phone
numbers (max. 5) according to set rules. This function may be necessary for
example in case of text message notifications of your account status. To add the
rules, press
. In the displayed window, you can enter up to 2 rules applying to
transferring text message commands: