EPX400-A20CU – Manual
Page 33 / 62
Entry time
8.3.2.
After clicking on this option an additional list will show, where you can set the time
for entry. Time after which alarm will be generated after delayed input had been
armed and partition to which delayed input belongs will not be disarmed.
Arming input
8.3.3.
After clicking on this option, partition arming input can be selected. To selected
input, arming device (remote controller receiver output or electronic keypad NO/NC
output for instance) is connected. When this input is armed, partition is armed (after
Exit Time, see below). When arming input is disarmed, partition is disarmed.
Connected wired inputs
8.3.4.
Assigning input to partition means that it is monitored only when partition to which
input belongs is armed. Input can be assigned up to one partition. Arming inputs can
not be assigned to any partition. If input is not assigned to any partition, it acts as
24 hours input – it is monitored regardless of partitions state.
8.4.
INPUTS/OUTPUTS
Communicators have 9 inputs, two OC type outputs and one relay output. The
"Input/Output" option allows to configure the communicator in accordance with the
requirements of the user.
Wired inputs
8.4.1.
For every input the following settings shall be determined respectively