EPX400-A20CU – Manual
Page 36 / 62
enter full phone number or only a part of number. The device will detect all numbers
with specified sequence. E.g. if entered number is
1234
, the output will activate
after incoming call from number
1234
56789 or 600
1234
56.
Note: The phone number must be entered without country code (e.g. without prefix
0048 and +48).
Dependent on state transitions from non-active to active of one of the inputs.
Outputs can be also activated by internal watchdog.
Advanced outputs control
8.4.2.3.
The user is able to determine an alternative course of action to go over basic outputs
configuration function described in 8.4.2.1 and 8.4.2.2.
In the “Advanced outputs control” you may define separately the behavior of each of
the outputs, depending on events taking place. “Advanced outputs control” differs
from the existing basic “Outputs configuration” by:
o
making it possible to not only to turn on but also to turn off the output
o
output can be activated temporarily for specified amount of time
o
there is a complete list of events for which you can define the behavior of the
output.
Note: Do not use the basic configuration of outputs (1 ) and the “Advanced
outputs control” at the same time!
In particular, the basic configuration of existing options: “No GSM signal
(immediately after detection)” and “Dependent on state transitions from non-active
to active of one of the inputs” should not be used with their replacements “[Off]
GSM” and “[On] Input x”. The use the basic configuration of outputs and “Advanced
outputs control” at the same time, may cause unexpected behavior of the
communicator.
Time of output activation
8.4.2.3.1.
Parameter defining amount of time for which the output is to be turned on for the
functions of advanced outputs control.
Events
8.4.2.3.2.
These columns define which events are to influence the status of a specific output.
Possible choices are:
o
Do Nothing – output status will be not changed (default action).
o
Turn on output – output will be permanently turned on.
o
Turn on output temporarily – output will be turned on for an amount of time
specified by parameter 8.4.2.3.1
o
Turn off output – output will be turned off.
The output state does not change if the current state of the output coincides with the
result of the action.