21
Instruction Manual IM02602008E - Rev. D
Transformer Temperature Controllers
IM02602008E - Rev. D May 2019 www.eaton.com
2. Scroll to
MODBUS
using the
and
arrows.
3. Press
Select
. A sub-menu displays.
4. Scroll to
PARITY
using the
and
arrows.
5. Press
Select
. A sub-menu displays.
6. Scroll to
ODD
,
EVEN
, or
NONE
, using the
and
arrows.
7. Press
Select
to enter your choice.
PARITY
displays.
8. Press
Back
once to return to the Modbus menu or
twice to exit the program.
4.1.2.2.5.3 Stopbits (MODBUS/STOP-BIT) (TC-50 Modbus and
TC-100)
Selects Modbus stopbit desired, between
One
or
Two
. The
default is
Two
.
1. Press
Prog
and enter your password. A sub-menu
displays.
2. Scroll to
MODBUS
using the
and
arrows.
3. Press
Select
. A sub-menu displays.
4. Scroll to
STOP-BIT
using the
and
arrows.
5. Press
Select
. A sub-menu displays.
6. Scroll to
ONE
or
TWO
, Using the
and
arrows.
7. Press
Select
to enter your choice.
STOP-BIT
displays.
8. Press
Back
once to return to the Modbus menu or
twice to exit the program.
4.1.2.2.5.4
Modbus Address (MODBUS MB-ADDRS)
(TC-50 Modbus and TC-100)
Selects the Modbus address desired, between
1
and
247
.
The default is
1
.
1. Press
Prog
and enter your password. A sub-menu
displays.
2. Scroll to
MODBUS
using the
and
arrows.
3. Press
Select
. A sub-menu displays.
4. Scroll to
MB-ADDRESS
using the
and
arrows.
5. Press
Select
.
6. Scroll to the address desired, from 1 to 247, using the
and
arrows.
7. Press
Select
to enter your choice.
MB-ADDRESS
displays.
8. Press
Back
once to return to the Modbus menu or
twice to exit the program.
4.1.2.2.6 Input Channel Parameters (INPUT-CH)
This is the top level menu for setting the various thermo-
couple input channel parameters. Pressing
Select
at this
menu item to view a set of sub-menus to navigate through
the individual parameters..
4.1.2.2.6.1 Channel Display (INPUT-CH-DISPLAY)
Selects the channel identifier for display, from
ABC
,
123
, or
UVW
. The default is
ABC
.
1. Press
Prog
and enter your password. A sub-menu
displays.
2. Scroll to
INPUT-CH
using the
and
arrows.
3. Press
Select
. A sub-menu displays.
4. Scroll to
CH-DISPL
using the
and
arrows.
5. Press
Select
. A sub-menu will display.
6. Scroll to
A-B-C
,
1-2-3
, or
U,V,W
using the
and
arrows.
7. Press
Select
to enter your choice.
CH-DISPL
displays.
8. Press
Back
once to return to the Channel Display
menu or twice to exit the program.
4.1.2.2.6.2 Input Channel-ON/OFF Control (INPUT-CH/
CH-ON,OFF)
This is the 1st sub-level menu for setting the On/Off status
of thermocouple input channels. Pressing
Select
at this
sub-menu item provides another set of sub-menus to navi-
gate through the four channels. This is the first sub-level
menu for setting the On/Off status of thermocouple input
channels. Pressing
Select
at this sub-menu item provides
another set of sub-menus to navigate through the four chan-
nels.
4.1.2.2.6.3 Input 1(INPUT-CH/CH-ON or OFF/INPUT1)
Sets thermocouple On/Off control for input 1 to
ON
or
OFF
.
The default is
ON
.
1. Press
Prog
and enter your password. A sub-menu
displays.
2. Scroll to
INPUT-CH
using the
and
arrows.
3. Press
Select
. A sub-menu displays.
4. Scroll to
CH-ON.OFF
using the
and
arrows.
5. Press
Select
. A sub-menu displays.
6. Scroll to
INPUT 1
using the
and
arrows.
7. Press
Select
. A sub-menu displays.