3 - 12
Faults
Service Manual Cafitesse 100
07.2004
Error in water coil circuit
(safety circuit interrupts
supply after 5 sec.)
•
Open coil circuit: Defective
wiring, coil or control unit
•
Coil permanently live
•
Short circuit coil
Error in Peltier circuit (safety
circuit interrupts supply,
when flowing current
< 1A or > 4A)
•
No current supply of the
Peltier element
-
yellow LED at control unit
OFF:
Break down of fuse F04
in the power supply unit,
or of thermo fuse in
transformer T01 USA/
Canada.
Transformer T01 or
control unit defective
-
yellow LED at control unit
ON: Defective temperature
sensor or control unit
•
Circuit of the Peltier
element not connected,
short circuit or defective
control unit
Red LED: Flashing
Delivery: No
Cooling: Yes
Display:
-Error-
Water valve control
Red LED: Flashing
Yellow LED: Flash-
ing (short
frequency), when
cooling compartment
temperature > 11°C
(51.8°F)
Delivery: Yes
Cooling: No
Display:
-Error-
Peltier control
Fault
Possible cause
Remedy
•
Replace the control unit (see chap.
5K.2)
-
if not o.k. —> Check wiring
-
if o.k. —> change the coil
•
Change the control unit
(see chap. 5K.2)
•
Change the coil (see chap. 5K.2)
-
Disconnect plug ST07 from the control
unit, replace the fuse and check if
PINs 5 and 2 of transformer T01 carry
11V-14V.
If no voltage —> replace the
transformer and the fuse.
If voltage —> replace the control unit
(see chap. 5K.2).
-
Disconnect sensor BU05 from the
control unit.
Check if PINs1 and 3 of BU06 carry
+12V.
If voltage —> replace the sensor.
If no voltage —> replace the control
unit (see chap. 5K.2).
•
Replace the control unit.
If not o.k. —> replace the cooling unit
(see chap. 5K.2)
3.2.7 Indicated Malfunctions
Содержание Cafitesse 100
Страница 4: ......
Страница 6: ......
Страница 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Страница 50: ...3 14 Faults Service Manual Cafitesse 100 07 2004 3 3 Faults occurred in the Market and their Solutions ...
Страница 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Страница 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Страница 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Страница 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Страница 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Страница 137: ...07 2004 5B 1 Functions Brewing System Service Manual Cafitesse 100 B Brewing System Not available ...
Страница 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Страница 139: ...07 2004 5C 1 Functions Dosing System Service Manual Cafitesse 100 C Dosing System C 1 Adjustments Not required ...
Страница 152: ...07 2004 5C 14 Functions Dosing System Service Manual Cafitesse 100 C 7 Accessories Not available ...
Страница 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Страница 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Страница 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Страница 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...