2 - 21
Installation / Putting into Operation
Service Manual Cafitesse 100
07.2004
2.7 Technical Data
(Total Overview)
Dimensions:
Height: 645 mm (25.39 in) (C110/C120)
Width:
210 mm (8.27 in)
Depth:
455 mm (17.91 in)
Weight:
21 kg (46.3 lbs) (empty)
Water connection*:
3/4'' connection to inlet valve
Drinking water line with stop valve.
Connection to warm water line only with matching feedings
Supply system requirements:
Water inlet temperature:
max. 75°C (167°F)
Dynamic pressure:
min. 0.8 bar at 6 l/min(11.6 psi
at 1.32 UK gal/min/1.59 US gal/min)
Static pressure:
max. 10 bar (145 psi)
Tank top version:
Tank on the dispenser for manual filling.
Capacity:
4 l (0.88 UK gal/1.06 US gal)
Cold water connection
Dynamic pressure:
min. 0.8–4 bar at 1.2 l/min(11.6-58.02 psi
for café cool (option):
at 0.26 UK gal/min/0.32 US gal/min)
Static pressure:
max. 7 bar (101.53 psi)
Water filling amount:
6.5 l (atmospheric boiler) (1.43 UK gal/1.72 US gal)
Concentrate capacity:
Coffee and tea flexy-pack with 2 litres contents each
(0.44 UK gal/0.53 US gal)
Electrical
Tolerance
Voltage
Heat capacity
Total output
Connection values:
(over- and
undervoltage)
100 V
+/-10 %
1.4 kW
1.6 kW
120 V
+/-6 %
1.4 kW
1.6 kW
200 V
+/-10 %
3.0 kW
3.2 kW
230 V
+6 %/-10 %
2.0 kW
2.2 kW
230 V
+6 %/-10 %
2.7 kW
3.0 kW
230 V
+6 %/-10 %
3.0 kW
3.2 kW
240 V
+/-6 %
3.0 kW
3.2 kW
240 V
+/-6 %
2.7 kW
2.9 kW
Electric connection:
A fuse must be provided in the mains supply line
Length of power
approx. 1.80 m (70.87 in = 5.9 ft)
supply cable:
The dispenser is delivered with national power supply cable.
Содержание Cafitesse 100
Страница 4: ......
Страница 6: ......
Страница 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Страница 50: ...3 14 Faults Service Manual Cafitesse 100 07 2004 3 3 Faults occurred in the Market and their Solutions ...
Страница 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Страница 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Страница 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Страница 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Страница 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Страница 137: ...07 2004 5B 1 Functions Brewing System Service Manual Cafitesse 100 B Brewing System Not available ...
Страница 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Страница 139: ...07 2004 5C 1 Functions Dosing System Service Manual Cafitesse 100 C Dosing System C 1 Adjustments Not required ...
Страница 152: ...07 2004 5C 14 Functions Dosing System Service Manual Cafitesse 100 C 7 Accessories Not available ...
Страница 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Страница 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Страница 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Страница 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...