07.2004
5K - 13
Functions - Power Supply and Control
Service Manual Cafitesse 100
Ferrit
sleeve
(14,
Fig.
1)
Interference
filter
(12,
Fig.
1)
Voltage
selector
(13,
Fig.
1)
220 V
208–240 V/
208-220 - 240 V/ 220 V Europe
0.315 AT
0.5 AT
+
-
+
Europe
13 V
25 V
115 V
120 V/
115 V/
115 V USA
0.75 AT
1 AT
-
-
-
USA
13 V
25 V
240 V
208–240 V/
208-220 - 240 V/ 240 V GB
0.315 AT
0.5 AT
+
-
+
GB
13 V
25 V
100 V
100 V/
100 V/
100 V Japan
0.63AT
1 AT
+
-
-
Japan
12 V
24 V
208–240 V 208–240 V/
208-220 - 240 V/ 240 V USA
0.4 AT
0.75 AT
-
+
-
USA
13 V
25 V
200 V
200 V/
200 V/
200 V Japan
0.315 AT
0.5 AT
+
-
-
Japan
24 V
11.5 V
220 V
208–240 V/
208-220 - 240 V/ 220 V Switzerl.
0.315 AT
0,5 AT
+
-
+
Switzerland 13 V
25 V
240 V
208–240 V/
208-220 - 240 V/ 220 V Australia
0.315 AT
0,5 AT
+
-
+
Australia
13 V
25 V
Transformator
T01
(1, Fig. 1)
Power
supply
(Fig. 1)
Transformator
T02
(2, Fig. 1)
Power supply
cable
(6, Fig. 1)
Fuse
F04
(8, Fig. 1)
Fuse
F05
(9, Fig. 1)
Fig. 3
Fig. 2
1
2
1
2
•
The power supply is equipped with low
voltage transformators.
•
The transformator T 01 supplies the control
with secondary voltage.
•
With dispensers suitable for 208–240 V
operation delivered in the USA and
Canada, the primary supply of the T 02 is
connected to a voltage selector.
•
The boiler heating operates with mains
voltage and is supplied via the main switch
of the dispenser. The cooling system fan is
directly connected to the mains and
operates permanently.
•
The primary circuits at the T01 and T02
transformators are protected by the fuses
F04 (1) and F05 (2) which are mounted at
the rear of the power supply. (Fig. 2, 3)
The logic and Peltier supply can only
be interrupted by disconnecting the
dispenser from the mains supply.
The supply of the outlet valve, the flexi
coil and the Operating panel/interface
can be interrupted by means of the
main switch.
Содержание Cafitesse 100
Страница 4: ......
Страница 6: ......
Страница 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Страница 50: ...3 14 Faults Service Manual Cafitesse 100 07 2004 3 3 Faults occurred in the Market and their Solutions ...
Страница 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Страница 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Страница 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Страница 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Страница 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Страница 137: ...07 2004 5B 1 Functions Brewing System Service Manual Cafitesse 100 B Brewing System Not available ...
Страница 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Страница 139: ...07 2004 5C 1 Functions Dosing System Service Manual Cafitesse 100 C Dosing System C 1 Adjustments Not required ...
Страница 152: ...07 2004 5C 14 Functions Dosing System Service Manual Cafitesse 100 C 7 Accessories Not available ...
Страница 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Страница 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Страница 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Страница 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...