2 - 5
Installation / Putting into Operation
Service Manual Cafitesse 100
07.2004
Customer
Recommendation:
Water supply line with stop valve and non-
return valve.
Connection to hot water line only with
suitable supply lines.
Supply system
Temperature:
max. 75 °C (167 °F)
Dynamic pressure: min. 0.8 bar at 6 l/min.
(11.6 PSI at 1.32 UK gal/min/
1.59 US gal/min)
Static pressure:
max 10 bar (145 psi)
Dispenser
Connections for hoses:
R3/4''-3/8UNF USA/CAN
R3/4-R3/4 (Europe)
R3/4-R3/8 (The Netherlands)
USA: The dispenser must be installed with
an adequate return flow protection that
complies with local regulations.
2.2.2 Water Supply
CAUTION:
Check the drinking water quality before the installation especially when
installing a tank for manual filling.
A drinking water filter is recommended.
CAUTION:
When using new water pipes, flush them sufficiently before the installation.
Read local regulations carefully when choosing supply lines. Only use neutral
material with respect to taste.
Содержание Cafitesse 100
Страница 4: ......
Страница 6: ......
Страница 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Страница 50: ...3 14 Faults Service Manual Cafitesse 100 07 2004 3 3 Faults occurred in the Market and their Solutions ...
Страница 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Страница 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Страница 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Страница 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Страница 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Страница 137: ...07 2004 5B 1 Functions Brewing System Service Manual Cafitesse 100 B Brewing System Not available ...
Страница 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Страница 139: ...07 2004 5C 1 Functions Dosing System Service Manual Cafitesse 100 C Dosing System C 1 Adjustments Not required ...
Страница 152: ...07 2004 5C 14 Functions Dosing System Service Manual Cafitesse 100 C 7 Accessories Not available ...
Страница 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Страница 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Страница 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Страница 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...