3 - 4
Faults
Service Manual Cafitesse 100
07.2004
1. Connections to the power
supply or power supply
plug are unplugged
2. Mains fuse blown
1. Main switch OFF
2. Main switch defective
1. Fuse F05 of power supply
defective
2. Defective transformer T02
3. With dispensers equipped
with voltage selector:
Voltage selector adjusted
incorrectly or defective
4. Defective control unit
5. Key switch "off"
1. Control unit defective
2. Stop button defective
3. Cable harness defective
1. Check connections.
If not ok: Connect supply lines
correctly.
2. Insert correct fuse.
Check voltage of power supply socket
with voltmeter.
If the fuse blows again, the fault may
concern either heating (ground short
circuit), power supply (transformers),
or damage caused by water. When
mounting the dispenser: Check if the
dispenser heating capacity exceeds
that of the local supply network –>
replace the dispenser.
1. Switch the dispenser on.
2. Check the connections of the switch.
If the connections are okay, replace
the switch.
1. Check connection of the fuse F05
with multi-meter (adjust to Ohm).
If no connection: Replace the fuse.
2. Check the output for 25 V alternating
voltage (see chap. 5K - Electric
Diagramm).
If not 25 V: Replace the transformer.
3. Adjust the voltage selector to mains
voltage or replace it.
4. Replace the control unit (see chap.
5K.2).
5. Position the key switch to "on".
1. Replace the control unit
(see chap. 5K.2).
2. Replace the stop button.
3. Check the cable harness for
transmission.
If no transmission: Replace the cable
harness.
The dispenser does
not operate
No dispenser
function except for
cooling system
No function except
for cooling system
and heating
No STOP function
Fault
Possible cause
Remedy
3.2.1 General Malfunctions
Содержание Cafitesse 100
Страница 4: ......
Страница 6: ......
Страница 14: ...1 8 Preface and Safety Instructions Service Manual Cafitesse 100 07 2004 ...
Страница 50: ...3 14 Faults Service Manual Cafitesse 100 07 2004 3 3 Faults occurred in the Market and their Solutions ...
Страница 73: ...4 23 Programming Service Manual Cafitesse 100 07 2004 4 3 Reading further Data Not included ...
Страница 74: ...4 24 Programming Service Manual Cafitesse 100 07 2004 ...
Страница 82: ...07 2004 5 8 Functions Service Manual Cafitesse 100 ...
Страница 114: ...07 2004 5A 32 Functions Water System Service Manual Cafitesse 100 Fig 1 A 6 1 Café cool ...
Страница 136: ...07 2004 5A 54 Functions Water System Service Manual Cafitesse 100 ...
Страница 137: ...07 2004 5B 1 Functions Brewing System Service Manual Cafitesse 100 B Brewing System Not available ...
Страница 138: ...07 2004 5B 2 Functions Brewing System Service Manual Cafitesse 100 ...
Страница 139: ...07 2004 5C 1 Functions Dosing System Service Manual Cafitesse 100 C Dosing System C 1 Adjustments Not required ...
Страница 152: ...07 2004 5C 14 Functions Dosing System Service Manual Cafitesse 100 C 7 Accessories Not available ...
Страница 162: ...07 2004 5D 10 Functions Product Delivery Service Manual Cafitesse 100 ...
Страница 176: ...07 2004 5F 14 Functions Cooling System Service Manual Cafitesse 100 ...
Страница 184: ...07 2004 5G 8 Functions Housing Service Manual Cafitesse 100 ...
Страница 193: ...07 2004 5K 9 Functions Power Supply and Control Service Manual Cafitesse 100 ...
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 210: ...07 2004 5K 18 Functions Power Supply and Control Service Manual Cafitesse 100 ...