Configuration parameters, detail
Parameter and value
range, factory setting
=
bold
.
Parameter description
1
0 - 4
0
Installation type
Reference Para. 16.15.2 for AS
parameter detail.
2
ED250
-3 to 50
0
Reveal depth
0
Reveal is set in increments of
10 mm (3/8").
Reference Chapter 17, reveal
depth.
3
Tb
ED250
7 to 12
10
Door width
10
Door width is set in increments of
100 mm (4"), "10" = 1000 mm (39.4").
Reference Chapter 17, door width.
4
0 to 4
0
Door type
0
Single door
1
Double door
• Overlapping door (with astragal)
• Active door operator.
2
Double door
• Overlapping door (with astragal)
• Passive door operator.
3
Double door
• Edgeless door (no astragal)
• Active door operator.
4
Double door
• Edgeless door (no astragal)
• Passive door operator.
20.1.9
Driving parameters - adjustments for low
energy operation, detail.
Parameter and value
range, factory setting =
bold
.
Parameter description
1
8 to 60
25
Opening speed, automatic mode
25
Parameter adjustment is in 0/
sec.
Maximum opening speed is
270/s in low energy mode.
2
8 to 60
25
Closing speed, automatic mode
25
Parameter adjustment is in 0/
sec.
Maximum closing speed is 270/s
in low energy mode.
2
Newtons
2 to 15 N:
*10
6
lb-f:
.45 to 3.4
*10
1.35
Static force in opening direction
6
Static force is set in Newtons.
Display value multiplied by 10 for
actual force.
1 Newton = .22 lbf.
60 Newtons = 13.5 lbf
Maximum static force is 15 lbf
in low energy mode measured
1" from latch edge of door at
any point in during opening or
closing.
3
Newtons
2 to 15 N:
*10
6
lb-f:
.45 to 3.4
*10
1.35
Static force in closing direction
6
Static force is set in Newtons.
Display value multiplied by 10 for
actual force.
1 Newton = .22 lbf.
60 Newtons = 13.5 lbf
Maximum static force is 15 lbf
in low energy mode measured
1" from latch edge of door at
any point in during opening or
closing.
TIPS AND RECOMMENDATIONS
Reference Chapter 36, ANSI/BHMA Standards,
Para. 36.2 for ANSI/BHMA A156.19 low energy
power operated door requirements.