44
ED250
08-2018
DL4614-070
dormakaba ED250 IG Installation Instructions
Chapter 16
16.3 Install cement cases, double door
Fig. 16.3.1 Cement cases installed in blockout
PVC 1 1/2” pipe and PVC reducer fittings
16.3.1 Set cement case into blockout
NOTICE
Reference applicable installation template
(Chapter 13) and contractor and/or architect
documentation to position cement case
spindles in blockout.
WARNING
Hand pinch point and crushing hazards!
1. Lower each cement case into blockout and shim case
into position.
TIPS AND RECOMMENDATIONS
PVC pipe and reducer fittings installed after
first anchoring cement pour in blockout
(Para. 16.6)