78
ED100/ED250
08-2018
DL4614-070
dormakaba ED250 IG Installation Instructions
Chapter 28
28.1 Upgrade cards
1
Upgrade card slot
2
Upgrade card
socket
Fig. 28.1.1 Upgrade card slot and socket
28.1.1 Upgrade card installation
dormakaba USA Inc. upgrade cards can be used to expand the
range of functions of the ED250 operator.
When upgrade cards are installed, information is exchanged
between and permanently allocated to both the operator control
unit and the upgrade card.
28.2 Container module
28.2.1 Container module
• The first upgrade card installed becomes
the container module.
• Every operator control unit has only one
container module.
• Functions of upgrade cards installed
after the first upgrade card are saved in
the container module.
28.2.2 Container module removal
• If the container module is removed, all
previously enabled functions will be
deactivated
after a certain time.
28.2.3 Operator control unit replacement
• If the control unit is replaced, the
container module is removed from the
old control unit and inserted into the new
control unit.
• The new control unit synchronizes with
the container module and all upgrade
card functions are available.
28.2.4 Inserting an upgrade card that has
already been activated
• Rapidly flashing yellow LED on upgrade
card indicates card is rejected.
• Card's functions in operator control unit
are still valid.
28.2.5 Inserted a container module from
third party control unit.
• Rapidly flashing yellow and green LEDs
on container module indicates module is
rejected.
• Container module can only be
synchronized with one control unit.
28.2.6 Container module defective
• Upgrade cards that were installed after
the container module must be
reinstalled.
Upgrade card
Upgrade card color
Fire protection
ED250
Transparent red
Professional
ED250
Green
DCW®
ED250
Yellow
Barrier free toilet
ED250
28.1.2 Upgrade cards
28 Upgrade cards
3
4
5
6
Status LEDs
3
Green LED
4
Yellow LED
5
Red LED
6
Upgrade card
professional (green)
1
2
Fig. 28.1.2 Upgrade card status LEDs