54
ED250
08-2018
DL4614-070
dormakaba ED250 IG Installation Instructions
Chapter 16
16.15.3
Initiate learning cycle to rotate spindle to door hanging position
Fig. 16.15.3.1 Arm and cement case cover installed;
center hung arm RH pull example
1
Spindle
2
Pivot arm
(center hung arm shown
as example)
16.15.3.1 Install cement case cover and arm on
spindle.
TIPS AND RECOMMENDATIONS
• Temporary installation of arm on spindle is
required for learning cycle.
• When learning cycle is initiated, spindle
first rotates to find door closed location.
Since the door is not installed, a block
(wood or other material) must be placed
at the door closed location.
1. Secure arm to spindle with supplied hardware.
2. Place block on floor with edge of block in door closed
location.
CAUTION
Block must be placed against arm in the arm
door closing direction.
3. Block must not contact cement case gasket!
16.15.3.2 Initiate learning cycle to rotate spindle.
CAUTION
Braking circuit plug (Para. 16.15.1) and
AS
parameter (Para. 16.15.2) must be set before
initiating partial learning cycle.
CAUTION
Temporary block must be secured or held in
place at door closed location during learning
cycle. Stay clear of arm travel path during
learning cycle!
Step 1
Press
Press and hold down button until display
changes.
• Spindle first rotates to door closed
location. Display shows a sequence
of symbols.
• Spindle will start to rotate in door
open direction.
Step 2
• Spindle stops.
• Display indicates spindle is at 70°
position for hanging door.
16.15.3.3 Remove block.
16.15.3.4 Remove arm.
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s
Fig. 16.15.3.2 Center hung arm
Fig. 16.15.3.3 Offset pivot arm
Fig. 16.15.3.4 Arm for slide track
Fig. 16.15.3.5 User interface
2
1
Edge of block at door close position
Door opening direction
Initial arm movement to door close position
CAUTION
Do not turn off power!
System is ready for door installation.