9. Plug cables into the back of the polishing machine connectors.
The 5-pin cable goes into AUX-1 connector and 7-pin cable goes
into AUX-2 connector. There is a RED dot on the top side of cable
connector to match the RED dot on AUX connectors to orient the
connectors to align the pins correctly.
47
10. Load a Micro-G® compatible Polishing
Fixture and secure with the standard Fixture
Screw. Rotate the Thumb Screws clockwise
so the cross pins on the Fixture Latching
Rods goes in the Latch Ring on the Polishing
Fixture. Hold the Polishing Fixture up and
push down on the Thumb Screw to engage
the cross pin. Rotate the Thumb Screws a
quarter turn clockwise to latch. Always
rotate the Thumb Screws clockwise when
latching or unlatching to prevent the screws
from unthreading from the Latching Rod.
11. When using non-Micro-G®
Polishing Fixture, a Retro-Fit Collar Assembly Kit
(MG1010) is required to be installed onto the
Polishing Fixture.
12. Remove Thumb Screw & Latching Rod
from Retro-Fit Collar Assembly by
turning Rods 90 Degree.
13. Install Retro-Fit Collar onto Fixture Post.
a. Remove the Retractable Fixture Screw. Push in while
turning screw out. A little dab of lock-tight was used to
hold in place.