Defining Steps within a Process:
Index tab “A” page 1 allows you to define Time, Speed, Platen
Direction, Speed Ramp Up, Pressure, Pressure Ramp Up, and Auto
Start for each step in the process. Press the long down arrow on the
far right to navigate to index tab “A” page 2. This page allows you to
define a Delay Pressure Apply, Speed Ramp Down, Pressure Ramp
Down, Polisher Fixture Weight, Polisher Recipe Op Code and End
Step Warnings.
Index tab “B” allows you to select Pad, Lubricant, Film, and Step
Notes for each step. Press the long down arrow on the far right to
navigate to index tab “B”, page 2. This page allows you to define a
Film Change Interval and A™ parameters.
Fig. 8A
1. Select tab “A” (Fig. 8A).
2. Select the “Time” box to access the keypad. Enter the number of
seconds to run this step. Select “OK”.