14
999805002 - 09/2018
System description
User Information
Load-bearing tower Staxo 40
Many possible ways of connecting couplers
On vertical tubes – Staxo
40 frame 1.80m
a ... max. 25
cm (this stays within the max. distance of 16cm which
EN 12812 stipulates from the node point of the centre-lines of the
load paths)
Staxo
40 frames 1.20m and 0.90m
a ... max. 25
cm (this stays within the max. distance of 16cm which
EN 12812 stipulates from the node point of the centre-lines of the
load paths)
On the horizontal profile – on all types of frame
a ... 34
cm
b ... 11
cm
On the screwjack head and base units
On the
70cm long screwjack head and base units
,
Swivel couplers 48mm or Normal couplers 48mm can
be fastened to the threadless section of the tube.
Also, a Screw-on coupler 48mm 95 can be mounted to
the holes in the threadless section of tube on all 70cm
long screw-jack U-heads and feet.
A
Swivel coupler 48mm or Normal coupler 48mm
A
Swivel coupler 48mm or Normal coupler 48mm
98024-209-01
A
A
a
a
98024-209-02
A
a
a
B
Screw-on coupler 48mm 95
Staxo 40 4-way
screw-jack head
70cm
Staxo 40 screw jack
U-head 70cm
Staxo 40 screw-jack
foot 70cm
A
Swivel coupler 48mm or Normal coupler 48mm
B
Scaffold tube 48.3mm
NOTICE
For information on dimensioning braced
screw-jack heads and feet, see the type spec-
ification sheet.
98024-233-01
B
a
b
98024-306-01
A
C
98024-306-02
A
C
98024-306-03
A
C
98024-307-01