64
999805002 - 09/2018
General remarks
User Information
Load-bearing tower Staxo 40
Tip-up protection for towers during
erection
To ensure safety during erection of the towers, suitable
precautions must be taken to prevent them tipping over
after they have reached a height of max. 6 m (or less, if
necessitated by the result of a hazard assessment).
using Doka Express anchor 16x125mm
➤
Screw in 1 Express anchor for each screw-jack foot.
Back-stays directly on the load-bearing tower
Horizontal fixing to the structure
NOTICE
The whole tower unit must be linked together
in a crane-handling-safe way using Staxo 40
anti-dropout locks and Staxo 40 tube connec-
tors.
See the section headed 'Lifting by crane'
A
Doka express anchor 16x125mm
Max. tensile force per leg: 5
kN
A
98024-281-01
A
Scaffolding tube 48.3mm (with drilled hole
⌀
17mm)
B
Normal coupler 48mm
C
Spindle connecting plate T
D
Back-stay for load-bearing towers
E
Tie-rod 15.0mm
See the section headed 'Anchoring on the
structure'.
E
D
98003-308-01
C
A
B