24
999805002 - 09/2018
System description
User Information
Load-bearing tower Staxo 40
on single-storey towers
Note:
For towers consisting of one 'storey' only, the min. val-
ues L
K
and L
F
stated for the screwjack head and base
units in the previous Tables will often not be reached.
Reason:
The lengths of the screwjack head and base
units in the frame add up to a larger dimension than the
height of the frame.
a
b
Staxo 40 screw-jack foot 30cm
50.7
--
Staxo 40 screw-jack foot 70cm
100.5
--
Staxo 40 screw-jack U-head 30cm
--
50.8
Staxo 40 screw-jack U-head 70cm
--
100.7
Staxo 40 4-way screw-jack head 30cm
--
50.8
Staxo 40 4-way screw-jack head 70cm
--
100.7
98024-212-01
a
b